Working principle
This product is a self-control valve. The medium enters from the bottom inlet. Because of the different density of gas and liquid, the gas will be discharged from the upper air outlet. The liquid will generate buoyancy on the float. During the floating of the liquid, the float The floating push pushes the sealing guide rod up, thereby sealing the air outlet, and realizing the function of the exhaust water blocking.
Technical Parameters
Working Pressure: Max 16 bar (232psi)
Body: CF8M
Sealing Material: FPM
Control Type: automatic
Medium Temperature: -20 °C - + 200 °C
Applicable Media: systems that can be used in hot water, cold water, and many other liquid media